Please use this identifier to cite or link to this item: http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/1616
Title: Análisis de calidad de la energía de inversor de puentes H y control SPWM
Other Titles: Energy quality analysis of CH-bridge inverter and SPWM control
Authors: López Monteagudo, Francisco Eneldo
Beltrán Telles, Aurelio
Beltrán González, Carlo Aurelio
Reta Hernández, Manuel
Morera Hernández, Mario
Issue Date: 20-Jan-2020
Publisher: Universidad Tecnológica de La Habana
Abstract: En este documento se muestran los resultados obtenidos al implementar un sistema de control por desplazamiento de nivel SPWM multicarrier a un inversor monofásico de puentes H en cascada. Las pruebas consistieron en usar tres métodos multicarrier con diferentes índices de modulación en frecuencia y amplitud. Obteniéndose un conjunto de resultados de los valores de los armónicos presentes en las mismas para cada método. El algoritmo de control fue programado usando el software SolidThinking Embed y el procesador digital de señales TMDSCNCD28379D de Texas Instruments se utiliza como interface con el inversor. Los resultados experimentales muestran que la calidad de la energía varía usando índices de modulación en frecuencia o en amplitud bajos con respecto a índices de modulación en frecuencia altos y modulación en amplitud cercanos a la unidad. Los resultados indican que la calidad de la energía mejora al incrementar los índices de modulación en frecuencia o amplitud.
Description: This document shows the results obtained by implementing a multicarrier SPWM level displacement control system to a singlephase seven level cascade H-bridge inverter. The tests consisted of using three multicarrier methods with different modulation rates in frequency and for every one different modulation rates in amplitude. Obtaining a set of results of the values of the harmonics present in them for each method. The control algorithm was programmed using SolidThinking Embed software and the digital signal processor TMDSCNCD28379D from Texas Instruments is used as an interface with the inverter. Experimental results show that energy quality varies using low frequency or amplitude modulation rates with respect to high frequency modulation rates and amplitude modulation rates close to unity. The results indicate that energy quality improves with increasing modulation rates in frequency or amplitude.
URI: http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/1616
https://doi.org/10.48779/zw68-vc60
ISSN: 1815-5901
Other Identifiers: info:eu-repo/semantics/publishedVersion
Appears in Collections:*Documentos Académicos*-- M. en Ciencias de la Ing.

Files in This Item:
File Description SizeFormat 
ARTICULO Análisis de calidad de la energía de inversor de puentes H y.pdfENERGIAS ALTERNAS712,52 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons