Repositorio Dspace

NaI(Tl) Scintillator's Response Functions for Point-like and Distributed Gamma-ray Sources

Mostrar el registro sencillo del ítem

dc.contributor 6207 es_ES
dc.contributor.other https://orcid.org/0000-0002-7081-9084 es_ES
dc.coverage.spatial Global es_ES
dc.creator Vega Carrillo, Héctor René
dc.creator Benites Rengifo, Jorge Luís
dc.creator Hernández Dávila, Víctor Martín
dc.creator Ortíz Rodríguez, José Manuel
dc.creator de León Martínez, Héctor Asael
dc.date.accessioned 2019-03-15T16:31:12Z
dc.date.available 2019-03-15T16:31:12Z
dc.date.issued 2016-08
dc.identifier info:eu-repo/semantics/publishedVersion es_ES
dc.identifier.issn 2321-8649 es_ES
dc.identifier.issn 2321-9289 es_ES
dc.identifier.uri http://localhost/xmlui/handle/20.500.11845/785
dc.identifier.uri https://doi.org/10.48779/cysr-0875 es_ES
dc.description.abstract The response functions of a NaI(Tl) detectors have been estimated using Monte Carlo methods. Response functions were calculated for monoenergetic photon sources (0.05 to 3 MeV). Responses were calculated for point-like sources and for sources distributed in Portland cement cylinders. Calculated responses were used to estimate the detector efficiency for pointlike and distributed sources. Samples of cylindrical Portland cement were prepared and exposed to the photoneutron field produced by a 15 MV linac used for radiotherapy. Short half-life radioisotopes were induced and the activity was determined by measuring the pulse-height spectra with a NaI(Tl) g-ray spectrometer that was calibrated using point-like sources. Instead of doing corrections due to differences between the geometry, material and solid angle of point-like sources used for calibration, and the Portland cement cylinders, the detection efficiency was determined using the ratio between the efficiencies for the point-like and the distributed sources estimated with the Monte Carlo calculations, and the activity of the induced isotopes in cement was obtained. es_ES
dc.language.iso eng es_ES
dc.publisher Chitkara University es_ES
dc.relation.uri generalPublic es_ES
dc.rights Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América *
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/3.0/us/ *
dc.source Journal of Nuclear Physics, Material Sciences, Radiation and Applications, Vol. 4, No. 1, agosto 2016, pp. 129–137 es_ES
dc.subject.classification CIENCIAS FISICO MATEMATICAS Y CIENCIAS DE LA TIERRA [1] es_ES
dc.subject.other Gamma- ray es_ES
dc.subject.other Point-like source es_ES
dc.subject.other Distributed source es_ES
dc.subject.other NaI(Tl) response es_ES
dc.subject.other Monte Carlo es_ES
dc.title NaI(Tl) Scintillator's Response Functions for Point-like and Distributed Gamma-ray Sources es_ES
dc.type info:eu-repo/semantics/article es_ES


Ficheros en el ítem

El ítem tiene asociados los siguientes ficheros de licencia:

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta

Estadísticas