Mostrar el registro sencillo del ítem
dc.contributor | 6207 | es_ES |
dc.contributor.other | https://orcid.org/0000-0002-7081-9084 | es_ES |
dc.coverage.spatial | Global | es_ES |
dc.creator | Vega Carrillo, Héctor René | |
dc.creator | Manzanares Acuña, Eduardo | |
dc.creator | Hernández Dávila, Víctor Martín | |
dc.creator | Arcos Pichardo, Arelí | |
dc.creator | Baquero, Raquel | |
dc.creator | Iñiguez de la Torre, María Pilar | |
dc.date.accessioned | 2019-03-15T15:00:55Z | |
dc.date.available | 2019-03-15T15:00:55Z | |
dc.date.issued | 2006-10 | |
dc.identifier | info:eu-repo/semantics/publishedVersion | es_ES |
dc.identifier.issn | 0094-243X | es_ES |
dc.identifier.issn | 1551-7616 | es_ES |
dc.identifier.uri | http://localhost/xmlui/handle/20.500.11845/770 | |
dc.identifier.uri | https://doi.org/10.48779/nb3e-ka43 | es_ES |
dc.description.abstract | The use of 131I is widely used in diagnostic and treatment of patients. If the patient is pregnant the 131I presence in the thyroid it becomes a source of constant exposition to other organs and the fetus. In this study the absorbed dose in the uterus of a 3 months pregnant woman with 131I in her thyroid gland has been calculated. The dose was determined using Monte Carlo methods in which a detailed model of the woman has been developed. The dose was also calculated using a simple procedure that was refined including the photons´ attenuation in the woman organs and body. To verify these results an experiment was carried out using a neck phantom with 131I. Comparing the results it was found that the simple calculation tend to overestimate the absorbed dose, by doing the corrections due to body and organs photon attenuation the dose is 0.14 times the Monte Carlo estimation. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | AIP Publishing | es_ES |
dc.relation | https://aip.scitation.org/doi/abs/10.1063/1.2356404 | es_ES |
dc.relation.uri | generalPublic | es_ES |
dc.rights | Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
dc.source | Medical Physics, Ninth Mexican Symposium on Medica Physics, AIP Conference Proceedings, Vol. 854, No. 1, octubre 2006 | es_ES |
dc.subject.classification | MEDICINA Y CIENCIAS DE LA SALUD [3] | es_ES |
dc.subject.other | Monte Carlo | es_ES |
dc.subject.other | Dosimetry | es_ES |
dc.subject.other | Thyroid gland | es_ES |
dc.title | Absorbed Dose in the Uterus of a Three Months Pregnant Woman Due to 131I | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
El ítem tiene asociados los siguientes ficheros de licencia: