Repositorio Dspace

Envíos recientes

*Documentos Académicos*-- UA Ciencias Nucleares: Envíos recientes

  • Barquero, Raquel; Mendez, Roberto; Vega Carrillo, Héctor René; Iñiguez de la Torre, María Pilar; Edwards, Taryn (Health Physics Society, 2005-01)
    Using the difference between responses to neutrons of TLD-600 and TLD-700, three experimental devices were constructed and arranged to measure thermal neutron fluences, neutron spectra, and neutron doses inside the treatment ...
  • Guzmán García, Karen Arlete; Gallego Díaz, Eduardo; Lorente, Alfredo; Borja Hernández, Candy Gretel; Valero Luna, Claudia; Hernández Dávila, Víctor Martín; Vega Carrillo, Héctor René (Sociedad Mexicana de Irradiación y DosimetríaUniversidad Autónoma Metropolitana, 2011-09)
    The response of a passive neutron monitor area has been calculated using the Monte Carlo code MCNP5. The response was the amount of n(6Li, T) reactions occurring in a TLD600 located at the center of a cylindrical ...
  • Guzmán García, Karen Arlete; Borja Hernández, Candy Gretel; Valero Luna, Claudia; Hernández Dávila, Víctor Martín; Vega Carrillo, Héctor René (Sociedad Mexicana de Física, A.C., 2012-06)
    La respuesta de un monitor de área pasivo para neutrones con pares de dosímetros termoluminiscentes TLDs ha sido calculada mediante métodos Montecarlo con el código MCNP5. La respuesta fue calculada para un TLD 600 localizado ...
  • Espinoza García, Guadalupe; Martínez Blanco, María del Rosario; León Pérez, Ana; Hernández Pérez, Cruz; Castañeda Miranda, Víctor Hugo; Solís Sánchez, Luis Octavio; Castañeda Miranda, Rodrígo; Vega Carrillo, Héctor René; Mendez Villafañe, Roberto; Gallego Díaz, Eduardo; de Sousa Lacerda, Marco Aurelio; Ortíz Rodríguez, José Manuel (Mesoamerican Centre for Theoretical Physics, 2016-09-28)
    Para la espectrometría y dosimetría de neutrones el Sistema Espectrométrico de Esferas Bonner ha sido el sistema más usado, sin embargo, el número, tamaño y peso de las esferas que componen al sistema, la necesidad de ...
  • Rodríguez Ibarra, Johanna Lizbeth; Hernández Adame, Pablo Luis; Vega Carrillo, Héctor René; Rivera Montalvo, Teodoro (Sociedad Mexicana de Irradiación y Dosimetría, 2015-09-30)
    Los equipos de rayos X para el diagnóstico se presentan en diferentes tamaños y formas que dependen del tipo de la exploración a realizar. El espectro de rayos X, es la distribución de energía de los fotones del haz y está ...
  • Ortíz Rodríguez, José Manuel; Martínez Blanco, María del Rosario; Vega Carrillo, Héctor René; Gallego Díaz, Eduardo; Lorente, Alfredo; Mendez Villafañe, Roberto; Los arcos Merino, José María; Guerrero Araque, Jorge Enrique (Sociedad Mexicana de Física A.C., 2011-02)
    La reconstrucción de espectros de neutrones y el cálculo de los equivalentes de dosis dependen de la energía de los neutrones, y por ello es esencial un conocimiento preciso de la espectrometría de los neutrones para ...
  • Guzmán García, Karen Arlete; Gallego Díaz, Eduardo; Vega Carrillo, Héctor René; González, Juan; Lorente, Alfredo; Ibañez Fernández, Sviatoslav (International radiation protection association, 2015-04-17)
    Debido al incremento en el control de mercancías para prevención del tráfico ilícito de material radiactivo y nuclear, en lucha contra el terrorismo nuclear, ha supuesto en numerosos países un aumento en el uso de sistemas ...
  • Gallego Díaz, Eduardo; Amgarou, Khalil; Bedogni, Roberto; Lorente, Alfredo; Mendez, Roberto; Vega Carrillo, Héctor René (Radiation Protection Association (IRPA), 2012-05)
    An automated panoramic irradiator with a 3 Ci 241Am-Be neutron source is installed in a bunker-type large room at the Universidad Politécnica de Madrid (UPM). It was recently modified and a neutron spectrometry campaign was ...
  • Ortíz Rodríguez, José Manuel; Martínez Blanco, María del Rosario; Cervantes Miramontes, José Manuel; Vega Carrillo, Héctor René (IntechOpen, 2013-01)
    Applications of artificial neural networks (ANNs) have been reported in literature in various areas. [1–5] The wide use of ANNs is due to their robustness, fault tolerant and the ability to learn and generalize, through ...
  • Vega Carrillo, Héctor René; Manzanares Acuña, Eduardo; Hernández Dávila, Víctor Martín; Mercado Sánchez, Gema Alejandrina; Gallego Díaz, Eduardo; Lorente, Alfredo (Sociedad Mexicana de Física, A.C., 2005-10)
    Mediante métodos Monte Carlo se han calculado los espectros de los neutrones producidos por 252Cf, 252Cf/D2O, 241AmBe, 239PuBe, 140LaBe, 239Pu18O2 y 226RaBe. Con la información del espectro se calculó la energía promedio ...
  • Medina Castro, Diego; Hernández Adame, Pablo Luis; Hernández Dávila, Víctor Martín; Sajo Bohus, Laszlo; Vega Carrillo, Héctor René (Machprinciple, 2015-09)
    En este trabajo se ha diseñado un reactor nuclear subcrítico heterogéneo con sales fundidas a base de torio, con moderador de grafito y una fuente 252Cf, cuyos niveles dosis en la periferia permita su uso en actividades ...
  • Vega Carrillo, Héctor René (Sociedad Mexicana de Física, A.C., 1988-01)
    En este trabajo se muestra la importancia que tienen las ecuadl>- nes diferenciales como herramienta para el estudio de la naturaleza. Se muestra un caso para enfatizar esta importancia, así como un diagrama de flujo ...
  • Escobedo Galván, Claudia Rafaela; Vega Carrillo, Héctor René; Dávila Hernández, Víctor (Machprinciple, 2015-09)
    Se diseño un mini reactor nuclear subcrítico formado por un medio moderador de agua ligera, uranio como combustible, una fuente isotópica de neutrones de 239PuBe. El diseño se hizo mediante métodos Monte Carlo con el ...
  • Vega Carrillo, Héctor René; Torres Muhech, Celia (Sociedad Mexicana de Física, A.C., 2002-10)
    Las aplicaciones de los neutrones comparten un mismo problema: el diseño de la fuente, En este trabajo el código MCNP se utilizó para diseñar una fuente de neutrones moderada a base de una funte isotópica de 239PuBe, con ...
  • Vega Carrillo, Héctor René; Barquero, Raquel; Mercado Sánchez, Gema Alejandrina (Novin Medical Radiation Institute, 2013-07)
    In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with ac ve detectors is useless; in these condi ons neutron measuring devices must have a passive detector. Here a passive ...
  • Vega Carrillo, Héctor René (Sociedad Mexicana de Física, A.C., 1989-08)
    \Ve discuss the problem of fitting an experimental data sel into a linear curve when experimental uncertainties can not be overlooked. Difficulties w¡th the standard least-squares method are pointed out. An alternative ...

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta