Repositorio Dspace

DNA Biosensor Based on Double-Layer Discharge for the Detection of HPV Type 16

Mostrar el registro sencillo del ítem

dc.contributor 5505 es_ES
dc.coverage.spatial Global es_ES
dc.creator Espinosa, José
dc.creator Galván, Marisol
dc.creator Quiñones, Arturo
dc.creator Ayala, Jorge
dc.creator Durón Torres, Sergio Miguel
dc.date.accessioned 2021-06-01T15:05:25Z
dc.date.available 2021-06-01T15:05:25Z
dc.date.issued 2019-09
dc.identifier info:eu-repo/semantics/publishedVersion es_ES
dc.identifier.issn 1424-8220 es_ES
dc.identifier.uri http://ricaxcan.uaz.edu.mx/jspui/handle/20.500.11845/2550
dc.description.abstract DNA electrochemical biosensors represent a feasible alternative for the diagnosis of different pathologies. In this work, the development of an electrochemical method for Human Papillomavirus-16 (HPV-16) sensing is reported based on potential relaxation measurements related to the discharge of a complex double layer of a DNA-modified gold electrode. The method used allows us to propose an equivalent circuit (EC) for a DNA/Au electrode, which was corroborated by electrochemical impedance spectroscopy (EIS) measurement. This model differs from the Randles circuit that is commonly used in double-layer simulations. The change in the potential relaxation and associated charge transfer resistance were used for sensing the DNA hybridization by using the redox pair Fe(CN)64-/Fe(CN)63+ as an electrochemical indicator. In order to determinate only the potential relaxation of the composed double layer, the faradic and double-layer current contributions were separated using a rectifier diode arrangement. A detection limit of 0.38 nM was obtained for the target HPV-16 DNA sequences. The biosensor showed a qualitative discrimination between a single-base mismatched sequence and the fully complementary HPV-16 DNA target. The results indicate that the discharge of the double-layer detection method can be used to develop an HPV DNA biosensor. es_ES
dc.language.iso spa es_ES
dc.publisher MDPI es_ES
dc.relation https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767228/#:~:text=The%20biosensor%20showed%20a%20qualitative,develop%20an%20HPV%20DNA%20biosensor. es_ES
dc.relation.ispartof 10.3390/s19183956 es_ES
dc.relation.uri generalPublic es_ES
dc.rights Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América *
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/3.0/us/ *
dc.source Sensors (Basel). 2019 Sep; 19(18): 3956. es_ES
dc.subject.classification BIOLOGIA Y QUIMICA [2] es_ES
dc.subject.other double layer discharge es_ES
dc.subject.other potential relaxation es_ES
dc.subject.other lectrochemical HPV-16 DNA biosensor es_ES
dc.subject.other DNA/Au electrode equivalent circuit es_ES
dc.title DNA Biosensor Based on Double-Layer Discharge for the Detection of HPV Type 16 es_ES
dc.type info:eu-repo/semantics/article es_ES


Ficheros en el ítem

El ítem tiene asociados los siguientes ficheros de licencia:

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América

Buscar en DSpace


Búsqueda avanzada

Listar

Mi cuenta

Estadísticas